How Bolts are Selected from the Specification


The steps in selecting a bolt from the Specification are as follows:

1.For each bolt in the set, get the BTYP values for each end of the bolt:Set the bolt item code from the bolt SPCOM name, and the bolt description from its detail and material texts.
1.If they are both set to BOLT, select the default bolt for that bolt diameter.
2.If they match and are not set to BOLT, select the bolt with that BTYP.
3.If they do not match, and one value is set to BOLT, select the bolt with BTYP set to the other BTYP.
4.If they do not match and neither is set to BOLT, select the bolt with BTYP set to the BTYP of the start of the bolt.

2.Set the bolt item code from the bolt SPCOM name, and the bolt description from its detail and material  texts.
3.Go to the SBOLT given by the BLTREF of the SPCOM:
 Get the values of BTYPs for items such as nuts and washers from the BITEMS array.
 Get the length values of these items from the BLIST array
 Get the extension thread length from the XLEN attribute.
4.Select the item by its BTYP and the current bolt’s BDIA. Get its item code from its SPCOM name and its  description from its detail and material texts.
5.Add its length to the accumulated bolt length.
6.Add the extension thread length to the accumulated bolt length
7.Go to the NSTD length table. If the accumulated length is within 1mm over an available length from the    BLEN array, then round down, else round up. If the NSTD reference is NULL, use the actual BLEN of the  SBOLT, since this is intended as a pre-set length for special purposes, for example, a large flange with exact  torque requirements.
8.Include the bolt length in the item code and description in accordance with the existing ISODRAFT  options.


When the bolt member count has been satisfied, combine the data to obtain totals of like bolt items in the material list.  Any error conditions such as a bolt item cannot be selected, or there are no long enough lengths in the NSTD table, will cause the system to generate an error message, output a material description of ”Bolts undefined” for that joint (with zero item code, size and quantity), and continue detailing.

PDMS Piping Tutorial: 1. Setting up the training module

1.Enter PDMS: START → ALL PROGRAMS → AVEVA → VANTAGE PDMS 11.6 → RUN PDMS
2.Login to SAM project (PDMS Sample Project) using SYSTEM username and password XXXXXX  (capital X six times).  Choose SAMPLE for the MDB and ADMIN for the module and click OK.  SYSTEM username is a free user that can  access all database. As default, the password for SYSTEM user  is XXXXX.
3.ADMIN module opened.
4.Show the command line. Select menu Display → Command Line

5.In command line type: SHOW !!TRARESET (watch for spelling) to display the Training Course Selection  Form.   There are 20 training options available. In this tutorial, you need to select training course number 1  and 2   only.
6.Select no (1) Basic Piping DESIGN Course and press Apply. The form will show that the training course    is now   set-up and ready. The training can be accessed in TRAINA MDB
7.Select number (2) Exercise 2 Basic Piping DESIGN Course. And then Apply
8.Exit form ADMIN module to MONITOE by selecting menu Admin →  Modules → Monitor...
9.You will be opted to Leave Admin and enter Monitor? Press Yes
10.The training can be accessed in TRAINA MDB. Change the MDB from SAMPLE to TRAINA.
11.Enter DESIGN module by choosing menu Monitor → Design → Macro Files…
12.Option: Leave Monitor and enter Design? Press Yes.